Tzovaras 2007.
Methods | Study: prospective randomised. Allocation: computer. Blinding: yes. | |
Participants | 386 patients: 193 P / 193 C. | |
Interventions |
Hernioplasty ATB: amoxicillin‐clavulanic 1,2 gr. MA: not standardised. Control: sterile saline. |
|
Outcomes | IP= 5; IC= 9 | |
Notes | ||
Risk of bias | ||
Bias | Authors' judgement | Support for judgement |
Random sequence generation (selection bias) | Low risk | Code numbers generated by the Arcus Quiqstat randomisation program using numbered sealed envelopes. |
Allocation concealment (selection bias) | Low risk | Quote: " The list with code numbers generated by the Arcus Quiqstat randomisation program was kept by a secretary, who was not involved in the treatment of the patients at any stage and was opened at the end of the trial for analysis of the results". |
Blinding (performance bias and detection bias) All outcomes | Low risk | Yes |
Blinding of participants and personnel (performance bias) All outcomes | Low risk | Yes |
Blinding of outcome assessment (detection bias) All outcomes | Low risk | Yes |