Tzovaras 2007.

Methods Study: prospective randomised. Allocation: computer. Blinding: yes.
Participants 386 patients: 193 P / 193 C.
Interventions Hernioplasty
ATB: amoxicillin‐clavulanic 1,2 gr. MA: not standardised. Control: sterile saline.
Outcomes IP= 5; IC= 9
Notes  
Risk of bias
Bias Authors' judgement Support for judgement
Random sequence generation (selection bias) Low risk Code numbers generated by the Arcus Quiqstat randomisation program using numbered sealed envelopes.
Allocation concealment (selection bias) Low risk Quote: " The list with code numbers generated by the Arcus Quiqstat randomisation program was kept by a secretary, who was not involved in the treatment of the patients at any stage and was opened at the end of the trial for analysis of the results".
Blinding (performance bias and detection bias) 
 All outcomes Low risk Yes
Blinding of participants and personnel (performance bias) 
 All outcomes Low risk Yes
Blinding of outcome assessment (detection bias) 
 All outcomes Low risk Yes