Skip to main content
. 2020 Apr 14;10:6371. doi: 10.1038/s41598-020-63395-9

Table 4.

Performance of X-ray and MRI architectures on test data. While integrated X-ray pipeline delivers higher accuracy than integrated MRI pipeline, integrated MRI pipeline yields improved sensitivity over integrated X-ray pipeline across all stages of OA, markedly so at no OA. Standard errors used to calculate confidence intervals.

OA status Image source Model type Accuracy (95% CI) Sensitivity (95% CI) Specificity (95% CI) Non-TKR cases TKR cases
None X-ray Non-imaging info. only 89.1 ± 0.139 49.7 ± 2.80 89.3 ± 0.140 2,892 12
Image only 95.0 ± 0.089 7.8 ± 1.64 95.4 ± 0.089
Integrated model 95.4 ± 0.081 8.6 ± 1.95 95.8 ± 0.077
MRI Non-imaging info. only 89.1 ± 0.139 49.7 ± 2.80 89.3 ± 0.140
Image only 95.2 ± 0.088 66.9 ± 3.23 95.3 ± 0.089
Integrated model 82.4 ± 0.171 92.2 ± 1.68 82.4 ± 0.173
Moderate X-ray Non-imaging info. only 72.9 ± 0.208 70.0 ± 1.16 73.0 ± 0.212 2,056 83
Image only 79.9 ± 0.196 66.7 ± 1.23 80.4 ± 0.195
Integrated model 81.4 ± 0.178 76.0 ± 1.12 81.6 ± 0.179
MRI Non-imaging info. only 72.9 ± 0.208 70.0 ± 1.16 73.0 ± 0.212
Image only 68.8 ± 0.225 78.3 ± 0.952 68.4 ± 0.227
Integrated model 74.9 ± 0.216 78.9 ± 0.974 74.7 ± 0.228
Severe X-ray Non-imaging info. only 51.3 ± 0.744 89.4 ± 0.864 35.8 ± 0.925 141 57
Image only 32.1 ± 0.714 94.5 ± 0.735 7.2 ± 0.467
Integrated model 60.5 ± 0.775 64.0 ± 1.57 59.0 ± 0.959
MRI Non-imaging info. only 51.3 ± 0.744 89.4 ± 0.864 35.8 ± 0.925
Image only 34.6 ± 0.775 98.3 ± 0.390 9.2 ± 0.632
Integrated model 59.6 ± 0.770 84.0 ± 1.03 49.6 ± 1.04
All X-ray Non-imaging info. only 81.1 ± 0.118 75.6 ± 0.776 81.2 ± 0.122 5,089 152
Image only 86.4 ± 0.095 72.5 ± 0.864 86.9 ± 0.095
Integrated model 88.4 ± 0.094 66.3 ± 0.924 89.1 ± 0.090
MRI Non-imaging info. only 81.1 ± 0.118 75.6 ± 0.776 81.2 ± 0.122
Image only 82.1 ± 0.118 84.9 ± 0.636 82.1 ± 0.119
Integrated model 78.5 ± 0.134 81.8 ± 0.643 78.4 ± 0.138