Table 59.6.

Cleaning of Noncritical Patient Care Items

Items Method
Ambu bag and mask Clean with detergent, dry, and thermally disinfect
Blood pressure apparatus and cuff Disinfect the cuff with 70–90% alcohol/other LLDs
Cloth appliances If reusable, clean with detergent and water, dry and disinfect with 70% alcohol
Doppler Head of the Doppler should be wiped with 70% alcohol
Bed and bed rails LLD
Gowns Single use in case of disposable, if reusable, use 0.5% bleaching powder, dry in sun/cloth drier
High-touch surface Clean with 70–90% alcohol twice a day
IV stand, IV monitoring pumps Clean with detergent and water and dry
Surgical mask Disposable/discard as per manufacturer’s recommendation
Stethoscope Clean the bell with 70–90% alcohol
Thermometer After every use wipe with 70–90% alcohol
Trolleys Wipe with 70–90% alcohol every day
Walls, wash basin clean with detergent and water

IV, intravenous; LLD, low-level disinfectant.