Skip to main content
. 2020 Jan 23;30(5):2955–2963. doi: 10.1007/s00330-019-06503-2

Table 5.

Shifts in radiation exposure in different sets of criteria for immediate total-body CT and standard workup with selective CT, n = 1083

Original criteria (15) Selected criteria (7) Selected and adjusted criteria (10)
Additional radiation exposure compared to STWU, mSv (95% CI) % of population Additional radiation exposure compared to STWU, mSv (95% CI) % of population Additional radiation exposure compared to STWU, mSv (95% CI) % of population
Selected for iTBCT
Severely injured 1.19 (− 0.13 to 2.51) 76.4 2.05 (0.56 to 3.53) 60.9 1.17 (− 0.23 to 2.57) 69.7
Non-severely injured 8.15 (5.91 to 10.39) 23.6 7.24 (3.07 to 11.41) 8.8 7.91 (4.77 to 11.05) 15.1
Additional radiation exposure compared to iTBCT, mSv (95%CI) % of population Additional radiation exposure compared to iTBCT, mSv (95% CI) % of population Additional radiation exposure compared to iTBCT, mSv (95% CI) % of population
Selected for STWU
Severely injured 2.11 (− 0.74 to 4.95) 15.4 − 1.32 (− 5.35 to 2.71) 6.7
Non-severely injured − 8.78 (− 11.44 to − 6.13) 14.9 − 8.78 (− 11.56 to − 6.01) 8.5

iTBCT immediate total-body CT, STWU standard workup with selective CT