Skip to main content
. 2020 Jan 31;30(5):2543–2551. doi: 10.1007/s00330-019-06636-4

Table 2.

Image features of near-occlusions detected and overlooked in routine practice. Single case of near-occlusion with full collapse mistaken for dissection/thrombosis excluded

Near-occlusions p
Detected (n = 21) Mistaken for conventional stenosis (n = 68) Mistaken for occlusion (n = 14)
Stenosis diameter mm mean (SD) 0.7 (0.2) 0.7 (0.2) 0.6 (0.4) 0.31*
Distal ICA diameter mm mean (SD) 1.9 (0.9) 2.4 (1.0) 0.8 (1.2) < 0.001*,†
Ipsilateral/contralateral distal ICA mean (SD) 0.48 (0.36) 0.53 (0.21) 0.18 (0.27) < 0.001*,†
Ipsilateral distal ICA/ECA mean (SD) 0.59 (0.30) 0.82 (0.44) 0.50 (1.07) 0.06*
Without full collapse, n (%) 7 (12) 48 (84) 2 (4) < 0.001#
With full collapse, n (%) 14 (30) 20 (43) 12 (26)

ECA, external carotid artery; ICA, internal carotid artery; SD, standard deviation

*One-way ANOVA

Post hoc: Only mistaken for occlusion group was separated from the two other groups at p < 0.05

#2-sided χ2 test