Table 2.
Image features of near-occlusions detected and overlooked in routine practice. Single case of near-occlusion with full collapse mistaken for dissection/thrombosis excluded
Near-occlusions | p | |||
---|---|---|---|---|
Detected (n = 21) | Mistaken for conventional stenosis (n = 68) | Mistaken for occlusion (n = 14) | ||
Stenosis diameter mm mean (SD) | 0.7 (0.2) | 0.7 (0.2) | 0.6 (0.4) | 0.31* |
Distal ICA diameter mm mean (SD) | 1.9 (0.9) | 2.4 (1.0) | 0.8 (1.2) | < 0.001*,† |
Ipsilateral/contralateral distal ICA mean (SD) | 0.48 (0.36) | 0.53 (0.21) | 0.18 (0.27) | < 0.001*,† |
Ipsilateral distal ICA/ECA mean (SD) | 0.59 (0.30) | 0.82 (0.44) | 0.50 (1.07) | 0.06* |
Without full collapse, n (%) | 7 (12) | 48 (84) | 2 (4) | < 0.001# |
With full collapse, n (%) | 14 (30) | 20 (43) | 12 (26) |
ECA, external carotid artery; ICA, internal carotid artery; SD, standard deviation
*One-way ANOVA
†Post hoc: Only mistaken for occlusion group was separated from the two other groups at p < 0.05
#2-sided χ2 test