Details of clinical outcomes.

Non-PD group PD group
Baseline Post HAL 1 M follow-up 3 M follow-up Baseline Post HAL 1 M follow-up 3 M follow-up
10 MWT (s) 23.3
[13.5, 46.3]
15.9
[10.8, 30.2]
(0.012)
16.3
[10.2, 25.3]
(0.012)
18.5
[10.3, 34.6]
(0.012)
15.3
[10.6, 26.7]
9.6
[8.5, 13.3]
(<0.001)
12.0
[9.4, 13.8]
(0.001)
10.4
[10.1, 10.9]
(0.006)
Step length (m) 0.38
[0.19, 0.43]
0.43
[0.26, 0.49]
(0.012)
0.46
[0.32, 0.53]
(0.012)
0.41
[0.24, 0.49]
(0.012)
0.37
[0.28, 0.47]
0.51
[0.42, 0.60]
(<0.001)
0.42
[0.40, 0.48]
(0.001)
0.52
[0.47, 0.57]
(0.003)
TUG (s) 30.1
[17.5, 47.0]
18.3
[11.3, 28.8]
(0.012)
20.5
[11.0, 31.6]
(0.012)
27.1
[13.1, 42.6]
(0.093)
17.7
[12.9, 22.7]
14.0
[10.1, 20.2]
(<0.001)
14.6
[11.5, 17.8]
(0.002)
11.7
[11.5, 18.3]
(0.136)
CST-30 (times) 4.5
[0.0, 7.3]
6.0
[3.8, 8.3]
(0.017)
6.0
[3.8, 9.5]
(0.011)
7.5
[3.8, 8.8]
(0.024)
4.0
[2.3, 4.3]
6.5
[5.8, 8.3]
(0.001)
7.0
[7.0, 9.0]
(0.001)
9.0
[6.8, 11.8]
(0.006)
VAS at rest 35.5
[23.3, 48.5]
8.0
[3.8, 16.3]
(0.036)
10.5
[1.5, 14.0]
(0.012)
23.0
[17.8, 28.5]
(0.233)
VAS in motion 49.0
[19.5, 55.3]
9.5
[4.5, 18.5]
(0.017)
11.0
[5.8, 17.8]
(0.028)
24.0
[10.8, 31.8]
(0.176)

10 MWT, 10 m walking test; CST-30, 30 s chair stand test; HAL, hybrid assistive limb; PD, Parkinson's disease; TUG, timed up-and-go test; VAS, visual analog scale.