Skip to main content
. 2020 Apr 16;30(9):4893–4902. doi: 10.1007/s00330-020-06829-2

Table 4.

Performance of the individualized prediction models

Primary cohort (n = 98) Validation cohort (n = 38)
Models AUC 95% CI Accuracy Specificity Sensitivity AUC 95% CI Accuracy Specificity Sensitivity
C model 0.952 0.915~0.988 0.888 0.894 0.882 0.967 0.919~1.000 0.868 0.859 0.842
R model 0.969 0.940~0.997 0.929 0.851 1.000 0.809 0.669~0.948 0.684 0.368 1.000
CR model 0.986 0.966~1.000 0.959 0.957 0.961 0.936 0.866~1.000 0.763 0.789 0.737

C, R, and CR indicate the predicted model based on clinical features, radiological features, and the combination of clinical features and clinical radiological features, respectively. CI confidence interval