Skip to main content
. 2020 Apr 3;2020:2867865. doi: 10.1155/2020/2867865

Table 2.

Parameters representing cardiovascular hemodynamics and LV performance in a steady cycle obtained from literature (Standard), from the model under control conditions (Control), and at TCV decreased to 50% (50% TCV).

Standard Control 50% TCV
P a,s 120 mmHg 125 mmHg 122 mmHg
P a,d 80 mmHg 80 mmHg 79 mmHg
(dPV/dt)max 1780 mmHg/s 1783 mmHg/s 1751 mmHg/s
V V,ed 120 ml 114 ml 114 ml
V V,es 40 ml 36 ml 37 ml
IVCD 60 ml 60 ms 71 ms
EPD 210 ml 211 ms 213 ms
EF 67% 69% 67%
CO 5600 ml/min 5653 ml/min 5538 ml/min
W LV 1.5 W 1.51 W 1.45 W

P a,s: systolic pressure in the aorta; Pa,d: diastolic pressure in the aorta; VV,ed: end-diastolic volume in the LV; VV,es: end-systolic volume in the LV; EPD: duration of ejection phase; EF: ejection fraction; CO: cardiac output; WLV: power of the LV. The standard values of parameters were taken from [6, 21].