Skip to main content
. Author manuscript; available in PMC: 2021 Mar 1.
Published in final edited form as: NMR Biomed. 2019 Dec 10;33(3):e4233. doi: 10.1002/nbm.4233

Table 2:

Pearson’s correlation coefficients of UTE-MRI bicomponent and tricomponent T2* results with microstructural and mechanical properties of cortical bone strips

μCT 4-point bending test
Porosity Pore size Young modulus Yield stress Ultimate stress Failure energy

Bicomponent model Frac BW −0.65
P<0.01
−0.61
P<0.01
0.52
P<0.01
0.52
P<0.01
0.54
P<0.01
0.44
P<0.01
T2* BW −0.47
P<0.01
−0.34
P<0.01
0.14
P=0.11
0.15
P=0.08
0.18
P=0.04
0.20
P=0.02
Frac PW 0.65
P<0.01
0.61
P<0.01
−0.52
P<0.01
−0.52
P<0.01
−0.54
P<0.01
−0.44
P<0.01
T2* PW 0.42
P<0.01
0.35
P<0.01
−0.13
P=0.12
−0.19
P=0.03
−0.20
P=0.02
−0.12
P=0.48

Tricomponent model Frac Fat 0.55
P<0.01
0.41
P<0.01
−0.41
P<0.01
−0.47
P<0.01
−0.46
P<0.01
−0.33
P<0.01
T2* Fat −0.14
P=0.11
−0.10
P=0.26
0.25
P<0.01
0.28
P<0.01
0.27
P<0.01
0.19
P<0.01
Frac BW −0.70
P<0.01
−0.61
P<0.01
0.58
P<0.01
0.61
P<0.01
0.62
P<0.01
0.48
P<0.01
T2* BW −0.58
P<0.01
−0.40
P<0.01
0.32
P<0.01
0.33
P<0.01
0.35
P<0.01
0.31
P<0.01
Frac PW 0.62
P<0.01
0.60
P<0.01
−0.55
P<0.01
−0.55
P<0.01
−0.57
P<0.01
−0.47
P<0.01
T2* PW 0.35
P<0.01
0.29
P<0.01
−0.04
P=65
−0.05
P=0.56
−0.05
P=0.53
0.00
P=0.27