Skip to main content
. Author manuscript; available in PMC: 2021 Apr 1.
Published in final edited form as: Med Phys. 2020 Feb 26;47(4):1763–1774. doi: 10.1002/mp.14065

Table 4.

Target Registration Error (TRE) values for the-state-of-art traditional methods on DIRLAB datasets

Set Before registration Conventional methods
Schmidt-Richberg et al.57 Heinrich et al.51 Fu et al.19 Delmon et al.17 Vandemeulebroucke et al.16 Staring et al.52 Elastix+MI
Gong et al.58
MIND
Li et al.59
ANTs+NCC
Heinrich et al.60
1 3.89±2.78 1.22±0.64 0.97±0.5 1.06±0.50 1.2±0.6 1.52±0.92 0.99±0.57 1.23 1.05 -
2 4.34±3.90 1.14±0.65 0.96±0.5 1.09±0.57 1.1±0.6 1.30±1.03 0.94±0.53 1.15 1.06 -
3 6.94±4.05 1.36±0.81 1.21±0.7 1.51±1.00 1.6±0.9 1.69±1.12 1.13±0.64 1.92 1.23 -
4 9.83±4.86 2.68±2.79 1.39±1.0 1.73±1.55 1.6±1.1 1.82±1.14 1.49±1.01 1.81 1.48 -
5 7.48±5.51 1.57±1.23 1.72±1.6 1.80±1.63 2.0±1.6 2.75±2.45 1.77±1.53 2.52 1.62 -
6 10.89±6.9 2.21±1.66 1.49±1.0 2.25±2.61 1.7±1.0 2.01±1.16 1.29±0.85 2.42 1.61 -
7 11.03±7.4 3.81±3.06 1.58±1.2 1.41±0.98 1.9±1.2 2.15±1.59 1.26±1.09 3.92 2.04 -
8 15.0±9.01 3.42±4.25 2.11±2.4 3.53±5.70 2.2±2.3 2.11±1.79 1.87±2.57 5.65 3.46 -
9 7.92±3.98 1.83±1.19 1.36±0.7 2.31±1.88 1.6±0.9 2.05±1.20 1.33±0.98 3.05 1.37 -
10 7.3±6.35 2.06±1.92 1.43±1.6 1.18±1.97 1.7±1.2 2.12±1.66 1.14±0.89 2.29 1.63 -
Mean 8.46±5.48 2.13±1.82 1.43±1.3 1.78±1.83 1.66±1.14 1.95±1.47 1.32±1.24 2.60±1.35 1.66 2.43±4.1