Table 4.

Effect of sensor set on model performance

Sensor Set Tremor Bradykinesia
Binary Multiclass Binary Multiclass
Combo 0.78 (0.70–0.86) 0.76 (0.68–0.83) 0.67 (0.61–0.74) 0.65 (0.59–0.71)
Accel 0.77 (0.67–0.87) 0.74 (0.65–0.82) 0.63 (0.57–0.70) 0.63 (0.57–0.68)
Gyro 0.79 (0.74–0.85) 0.77 (0.72–0.82) 0.68 (0.61–0.75) 0.64 (0.59–0.70)
Watch 0.79 (0.69–0.89) 0.77 (0.68–0.86) 0.63 (0.56–0.69) 0.61 (0.56–0.66)

Average and 95% confidence intervals of model performance (AUROC) to classify PD symptoms using different sensor sets