Table II.
Peak Expiratory Flows and Fitted Correlation Exponents (α) of Occupational Asthmatic Subjects in Three Occupational Scenarios
| Scenario | PEF (L min−1) | PEF (% Predicted) | COVc (%) | Skewness | α |
|---|---|---|---|---|---|
| I | 506.4 ± 26.1a | 80.6%b | 5.2 | 0.68 | 0.53 |
| II | 421.9 ± 59.9 | 67.1% | 14.2 | −0.23 | 0.78 |
| III | 357.7 ± 56.9 | 56.9% | 15.9 | 0.89 | 0.87 |
aMean ± standard deviation.
bAdopted from Nunn and Gregg( 11 ) in that predicted PEF for men: loge PEF (L min−1) = 0.544 loge age − 0.0151age − 74.7/height (cm) + 5.48. An aged 40 years old with a height of 170 cm male was estimated to be 628.5 L min−1 of predicted PEF.
cCoefficient of variation (COV) = standard deviation/mean.