Skip to main content
. 2020 Apr 10;2020:6573296. doi: 10.1155/2020/6573296

Table 3.

Left atrial appendage occlusion procedure details.

Parameters CBA + LAAC group (N = 42)
LAA characteristics
 LAA lobulation, n (%)
  One lobe 12 (28.6)
  Two lobes 18 (42.9)
  Three lobes 3 (7.1)
  Multi-lobes 9 (21.4)
 LAA opening diameter (mm) 21.2 ± 3.3
 LAA depth (mm) 25.3 ± 4.3
Device characteristics
 Device company, n (%)
  Lefort 22 (52.4)
  Lacbes 11 (26.2)
  WATCHMAN 9 (21.4)
 Device size (mm) 25.0 ± 3.0
 Compression ratio (%) 15.9 ± 4.6
Periprocedural details
 Implantation, success 41 (97.6)
 Released time (s), n (%)
  Once 40 (95.2)
  Twice 2 (4.8)
 Residual flow, n (%)
  ≤3 mm 5 (12.0)
  >3 mm 0 (0)
 Cardiac tamponade 0 (0)
 ◆Electroversion 2 (4.8)

Continuous variables are described as mean ± SD, while categorical variables as percentage (%). CBA, cryoballoon ablation; LAAC, left atrial appendage closure. ◆Electroversion was applied when atrial fibrillation recorded during the procedure.