Skip to main content
. 2006 Jul 19;2006(3):CD003087. doi: 10.1002/14651858.CD003087.pub2

Jensen 1997.

Methods Principle and first surgeons randomised to one of two groups using sealed envelopes. Details of method of randomisation not given. Perforations tested by filling with water, gently manipulating water into each digit and observing for leaks.
Participants Principle and first surgeons. Abdominal surgery. 200 single gloves and 200 double outer gloves were collected.
Interventions Single versus standard double gloves
Outcomes Number of perforations.
Notes  
Risk of bias
Bias Authors' judgement Support for judgement
Allocation concealment? Low risk A ‐ Adequate