Ablett 1995 |
Only double gloving was assessed. No comparison group was included. |
Adoumie 1994 |
A laboratory study, not a clinical study. Outcome was perception of temperature |
Albin 1992 |
Survey of single glove perforations only. Not an RCT |
Alwari 2001 |
Survey of all gloves used over period of time. Not an RCT |
Barbosa 2004 |
Survey of all gloves used over a period of time. Not an RCT |
Bebbington 1996 |
RCT of surgical closure using a surgical assist device |
Beck 1994 |
Discussion paper only |
Bennett 1991 |
Study looks at double gloves only. No comparison group included. |
Bennett 1994 |
Laboratory test of blood inoculation from needles and sutures |
Bliss 1992 |
Randomised controlled trial but compares brand A against brand B. No details are given of the differences between each brand |
Botet 1998 |
RCT of a surgical instrument used during wound closure |
Brown 1996 |
Study looks at glove indicator system only. No comparison group included |
Brownson 1990 |
A laboratory test, not a clinical study. |
Calliot 1997 |
Single versus double gloves but the outcome was electronic alarms rather than perforations |
Calliot 1998 |
Single versus double gloves but the outcome was electronic alarms rather than perforations |
Carter 1996 |
Insufficient randomisation. Study compares two types of single gloves; super sensitive and standard. |
Chapman 1993 |
Investigated double gloves only, no comparison group. |
Chen 1998 |
Laboratory test of various liners. |
Chiu 1993 |
Study looks at double gloves only. No comparison group. |
Cohen 1992 |
Study not randomised. |
Cohn 1990 |
Study not randomised. Outcome compared blood on hands not perforations |
Cole 1989 |
Study not randomised. |
Cox 1994 |
Laboratory test of different brands of testing methods using electronic equipment. |
Diaz Boxo 1991 |
Laboratory test rather than clinical trial |
Dirschka 2004 |
Survey of perforation rate of all gloves used over period of time. Not an RCT |
Dodds 1990 |
Study not randomised. |
Driever 2001 |
Not an RCT ‐ survey of all gloves used over period of time. |
Dupre 1999 |
A letter written in response to an article |
Eckersley 1990 |
Not randomised, surgeons chose which glove to wear. |
Eggleston 1997 |
RCT of surgical trays to reduce glove perforation |
Endres 1990 |
Study looks at double gloves only. No comparison group |
Faisal 2004 |
Survey of all gloves used over set period of time. Not an RCT |
Fay 1994 |
Study looked at perforation indicator gloves only. No comparison group. |
Fell 1989 |
Survey of perforated gloves. Not an RCT |
Fischer 1999a |
Study looked at perforation indicator gloves only. No comparison group. |
Fischer 1999b |
Laboratory test, not clinical trial. |
Florman 2005 |
Study of simulated surgery considering the speed of detection of the glove perforation. Perforations were created by laser. |
Gerberding 1990 |
An observational study, not randomised into groups |
Godin 1991 |
Observational study. No randomisation of interventions. |
Greco 1995 |
Study looks at double gloves only. No comparison group. |
Herscovici 1998 |
Laboratory test, not clinical trial. |
Hollaus 1999 |
Study measures double gloves only. No comparison group |
Housan 2000 |
Survey of all gloves used over period of time. Not an RCT |
Hwang 1999 |
Randomised controlled trial which compared four different manufacturers brands of gloves. Perforation rates were only shown in a diagrammatic form. |
Jackson 1999 |
Laboratory testing, not clinical trial |
Johanet 1995 |
Observational study of blood exposure. Not an RCT |
Johanet 1996 |
Observational study of blood exposure. Not an RCT |
Johnson 1991 |
Laboratory test of various gloving methods with contaminated suture needles |
Kelly 1993 |
Laboratory test on cadavers and patients. Not randomised. |
Kim 2001 |
Evaluation of glove wearing compliance following an educational programme. |
Konig 1992 |
Gloves were not randomised into different groups. |
Korniewicz 1994 |
Non clinical test of examination gloves. |
Kummer 1992 |
Laboratory test of liners |
Larkin 1993 |
Not a randomised study. Two surgeons ‐ 1 wore glove group A and the other surgeon wore glove group B |
Lavernia 1996 |
Not a RCT, allocation on a consecutive basis |
Lee 2001 |
An observational study of compliance. Not an RCT |
Leslie 1996 |
Laboratory test, not clinical trial |
Liew 1995 |
RCT . Intervention was one which was not addressed by this review ‐various combinations of standard and orthopaedic gloves. |
Logan 2000 |
Tested 5 different brands of gloves. Divided into groups, not randomised. |
Malhotra 2004 |
Survey of all double gloves used over period of time. Not an RCT |
Manson 1995 |
Study looks at glove indicator system only. No comparison group. |
Matta 1988 |
Study measures double gloves only. No comparison group. |
McCue 1981 |
Only double gloves were tested. No comparison group. |
McLeod 1989 |
Not randomised, surgeons chose which gloves to wear. |
Meyer 1996 |
RCT of surgical closure using different needles |
Nelson 1995 |
Gloves of varying thickness were tested in a laboratory for dexterity |
Newsom 1993 |
Study not randomised. |
Newsom 1998 |
Randomised controlled trial which compared latex free with latex gloves. |
Novak 1999 |
Laboratory test of sensation when wearing double or single gloves. |
Novi 1993 |
Literature review |
Panduro 1996 |
Not randomised. |
Patton 1995 |
Study looks at double gloves only. No comparison group. |
Phillips 1979 |
Non clinical test of dexterity when wearing Kevlar gloves |
Plucknet 1992 |
Measured blood contamination on hand ‐ not perforations. Does not state if it is a randomised study. |
Quebbeman 1992 |
Data from surgeons who did not comply with randomisation were still included in the study |
Rogers 2000 |
Systematic review. |
Rose 1994a |
Observational study of glove usage. Not an RCT |
Rose 1994b |
Observational study of glove usage. Not an RCT |
Salkin 1995 |
Laboratory test of glove liners |
Savitz 1994 |
Looked at double gloves only ‐ no comparison group |
Schwimmer 1994 |
Looked at double gloves only ‐ no comparison group |
Tokars 1994 |
Survey not an RCT. |
Tokars 1995 |
Observational study ‐ looked at blood on hands not perforations |
Tomichan 2000 |
Describes using a glove liner to cover the head of an orthopaedic prosthesis during surgery to prevent abrasions. |
Twomey 2003 |
Discussion paper and literature review |
Upton 1993 |
Looked at double gloves only ‐ no comparison group |
Vaughan‐Lane 1993 |
Study measures glove indicator system only. No comparison group |
Watts 1994 |
Laboratory test for dexterity only |
Webb 1993 |
Lab comparison of single versus double gloving for tactile discrimination and dexterity. |
Wigmore 1994 |
Study measures glove indicator system only. No comparison group. |
Williams 1997 |
Discussion paper on electronic testing of gloves. |
Woods 1996 |
Laboratory test for dexterity only |
Wright 1993 |
RCT of new suture |
Zimmerman 1996 |
Study measures glove indicator system only. No comparison group |