Skip to main content
. 2020 Apr 9;5(15):8605–8612. doi: 10.1021/acsomega.9b04497

Table 6. Arrhenius Parameter (A) in the Two Stages at Different Temperatures.

  first stage
Second stage
method 1173 1223 1273 1323 average 1173 1223 1273 1323 average
isoconversional method 0.190 0.614 1.080 2.332 1.054 0.072 0.114 0.556 1.412 0.538