Skip to main content
. 2020 Apr 2;13(7):1651. doi: 10.3390/ma13071651

Table 6.

Statistical test results for compressive strength of CFGPC and OPCC.

Mechanical Characteristics fc (MPa) ft (MPa) Ec (GPa)
Concrete Type OPCC CFGPC OPCC CFGPC OPCC CFGPC
Mean 36.91 37.35 3.29 3.54 28.06 18.97
Test date 28 day 7 day 28 day 7 day 28 day 7 day
F-test F = 2.46 < f0.05 = 2.81 F = 2.37 < f0.05 = 2.81 F = 1.72 < f0.05 = 2.81
Equal variances? Yes Yes Yes
T-test ts = 0.30 < t0.05 = 2.07
P = 0.77 > 0.05
ts = 1.52 < t0.05 = 2.07
P = 0.14 > 0.05
ts = 11.23 > t0.05 = 2.07
P = 1.4 × 10−10 < 0.05
Statistically significant difference? No No Yes