Experimental and predicted values for indirect tensile strength of GPC.

Researcher Experimental
ft (MPa)
Experimental
fc (MPa)
AS3600
ft (MPa)
CEB-FIP
ft (MPa)
ACI 363
ft (MPa)
Equation (4)
ft (MPa)
Current study 5.54 58.2 3.05 4.51 2.14 5.09
4.82 49.57 2.82 4.05 1.97 4.35
2.79 35.4 2.38 3.23 1.67 3.14
2.66 28.99 2.15 2.83 1.51 2.59
4.00 46.18 2.72 3.86 1.90 4.06
3.81 36.1 2.40 3.28 1.68 3.20
4.14 40.48 2.54 3.54 1.78 3.57
4.19 41.36 2.57 3.59 1.80 3.65
3.37 33.52 2.32 3.12 1.62 2.98
3.57 30.5 2.21 2.93 1.55 2.72
3.28 35.03 2.37 3.21 1.66 3.11
3.26 37.12 2.44 3.34 1.71 3.29
3.6 37.69 2.46 3.37 1.72 3.34
Sofi et al. [43] 3.2 35.2 2.37 3.22 1.66 3.12
2.9 44.4 2.67 3.76 1.87 3.91
2.4 37.6 2.45 3.37 1.72 3.33
3.6 41.8 2.59 3.61 1.81 3.69
3.5 42.0 2.59 3.63 1.81 3.70
2.7 38.3 2.48 3.41 1.73 3.39
Hardjito [20] 7.43 89 3.77 5.98 2.64 7.71
5.52 68 3.30 5.00 2.31 5.92
5.45 55 2.97 4.34 2.08 4.81
4.43 44 2.65 3.74 1.86 3.87
Rajini and Rao [40] 1.13 10.51 1.30 1.44 0.91 1.02
1.16 12.11 1.39 1.58 0.97 1.15
1.18 18.68 1.73 2.11 1.21 1.71
1.32 22.03 1.88 2.36 1.31 2.00
Chang [41] 3.62 37 2.43 3.33 1.70 3.30
2.96 30 2.19 2.90 1.53 2.69
4.96 55 2.97 4.34 2.08 4.88
4.48 48 2.77 3.96 1.94 4.26
2.96 30 2.19 2.90 1.53 2.69
2.93 29 2.15 2.83 1.51 2.60
4.65 51 2.86 4.13 2.00 4.53
Ryu et al. [42] 2.0 25.8 2.03 2.62 1.42 2.32
2.2 27.5 2.10 2.73 1.47 2.47
2.4 29.4 2.17 2.86 1.52 2.63
2.5 30.3 2.20 2.92 1.54 2.71
2.5 30 2.19 2.90 1.53 2.69
2.6 31.2 2.23 2.97 1.56 2.79