Figure 11.
Specific heat capacities following the dynamic DSC tests (for heating between 0 °C and 50 °C and cooling between 50 °C and 0 °C): (a) RT24, (b) RT26, (c) RT25 and (d) PureTemp 25. Note: the total specific heat capacities have been constructed by additively linking the sensible parts with the latent ones.