Skip to main content
. 2020 Mar 28;20(7):1884. doi: 10.3390/s20071884

Table 7.

Comparing evaluation parameters of one-phase and two-phase current signal.

KNN DT RF
2-phase signal 1-phase signal 2-phase signal 1-phase signal 2-phase signal 1-phase signal
Precision 0.97 0.90 0.98 0.91 0.99 0.91
F1-score 0.97 0.90 0.98 0.91 0.99 0.91
Sensitivity 0.989 0.86 0.989 0.91 0.994 0.92
Specificity 0.998 0.95 0.994 0.96 0.997 0.96
Accuracy (%) 97 89.70 98 91.03 99.7 91.12