Skip to main content
. 2020 Apr 14;2020:2421816. doi: 10.1155/2020/2421816

Table 4.

Visual and refractive outcomes one month after cataract surgery for all eyes.

Visual acuity
Preoperative corrected distance visual acuity 0.25 (SD 0.35)
Range 2.30 to −0.10
Postoperative uncorrected distance visual acuity 0.11 (SD 0.23)
Range 2.30 to −0.20
Postoperative corrected distance visual acuity 0.04 (SD 0.17)
Range 2.30 to −0.20
Change in corrected distance visual acuity −0.22 (SD 0.03)
Range 1.60 to −2.30

Refraction
Target spherical equivalent (D) −0.27 (SD 0.43)
Range from −3.82 to 1.84
Residual spherical equivalent (D) −0.16 (SD −0.48)
Range from −3.50 to 4.25
Difference between target and residual spherical equivalent (D) 0.11 (SD 0.41)
Range from −3.27 to 4.95
Absolute vale of difference between target and residual spherical equivalent (D) 0.28 (SD 0.31)
Range from 0 to 4.95

D: diopters. Visual acuity is reported as LogMAR value