Skip to main content
. 2020 Apr 2;20(7):1998. doi: 10.3390/s20071998

Table 2.

Interday reliability at the medial tibial plateau and the patella for the standing up and sitting down movements 1.

ICC 95% Confidence Interval SEM SEM% CV
Lower Limit Upper Limit
Medial tibial plateau
Standing up MPF 0.24 −0.26 0.64 31.27 Hz 15 0.11
amplitude 0.33 −0.16 0.69 4.19 dB 0.04
Sitting down MPF 0.33 −0.16 0.69 35.39 Hz 17 0.14
amplitude 0.27 −0.22 0.66 4.39 dB 0.04
Patella
Standing up MPF 0.62 * 0.22 0.85 15.64 Hz 9 0.07
amplitude 0.16 −0.33 0.59 6.27 dB 0.05
Sitting down MPF 0.82 * 0.56 0.93 13.56 Hz 7 0.08
amplitude 0.00 −0.51 0.42 6.85 dB 0.06

1. MPF = median power frequency; ICC = intraclass correlation coefficient; amplitude = sound signal amplitude; SEM = standard error of measurement; CV = coefficient of variation; * significance level p < 0.05.