Skip to main content
. 2020 Apr 27;10:7025. doi: 10.1038/s41598-020-63975-9

Table 4.

Examples of minibeam size (FWHM), PVDR and valley doses evaluated at different depths for treatment plans 3 and 4. The PVDR uncertainties are the standard deviation of the PVDR, as defined in section II.3.

Depth (mm) ctc: 4 mm ctc: 6 mm
Beam size (mm) PVDR Valley dose (%) Beam size (mm) PVDR Valley dose (%)
(a) Glioma (field 2)
1 0.7 19.2 ± 1.5 6.2 1.0 29.1 ± 1.9 6.2
10 0.7 17.5 ± 0.6 6.5 1.1 29.1 ± 0.9 6.5
20 0.9 12.8 ± 0.8 7.1 1.2 23.9 ± 1.3 6.9
40 1.2 7.1 ± 0.7 7.5 1.6 16.2 ± 1.4 7.1
60 1.7 3.6 ± 0.2 8.3 2.0 10.8 ± 0.9 12
80 2.1 1.2 ± 0.1 71 3.1 1.5 ± 0.1 61
90 2.2 1.1 ± 0.1 93 3.2 1.4 ± 0.2 84
ctc: 4 mm ctc: 6 mm
Depth (mm) Beam size (mm) PVDR Valley dose (%) Beam size (mm) PVDR Valley dose (%)
(b) Meningioma (field 1)
1 0.7 16.8 ± 2.3 5.2 0.8 44 ± 18 5.1
10 0.7 12.4 ± 1.5 5.8 0.8 35 ± 1 5.3
20 0.8 9.2 ± 0.4 6.1 0.8 22.6 ± 0.7 5.5
40 1.2 5.2 ± 0.2 7.0 1.5 13.6 ± 0.4 5.7
60 2.0 2.4 ± 0.1 9.1 2.6 7.0 ± 0.3 6.5
80 2.3 1.3 ± 0.1 13.5 3.2 2.9 ± 0.1 21
90 2.4 1.1 ± 0.2 73 3.2 1.6 ± 0.2 65