Skip to main content
. Author manuscript; available in PMC: 2020 Apr 28.
Published in final edited form as: Otol Neurotol. 2015 Sep;36(8):1343–1348. doi: 10.1097/MAO.0000000000000829

TABLE 4.

Implants fully inserted in ST

Residual hearing 1 month
Characteristic Overall (n = 38) No (n = 16) Yes (n = 22) P
Median (IQRa)
Age at implant 67.9 (57–74) 67.3 (56–73) 67.9 (57–75) 0.646
Depth of insertion 429.0(373–512) 394.0 (347–497) 453.5 (375–517) 0.287
n n (%)
Side 0.511
 Left 19 7 (36.8) 12 (63.2)
 Right 19 9 (47.4) 10 (52.6)
Model 0.929
 LW 25 10 (40.0) 15 (60.0)
 MS 2 1 (50.0) 1 (50.0)
 PM 11 5 (45.5) 6 (54.5)
Procedure 0.253
 Cochleostomy 4 3 (75.0) 1 (25.0)
 ERW 5 1 (20.0) 4 (80.0)
 RW 28 12 (42.9) 16 (57.1)
Sexb
 Male 15 9 (60.0) 6 (40.0) 0.400
 Female 8 3 (37.5) 5 (62.5)
a

25th to 75th interquartile range.

b

Single ear implants only.