Figure 5.

Figure 5

(A) Electrolyte resistance versus conductivity comparison between acrylic thread (diameter 670 µm) and surgicryl PGA (USP 0). Electrolytes were 5 mM Tris/HEPES (0.0159 S/m), 50 mM Tris/HEPES (0.141 S/m), 2.5% PBS (0.293 S/m), and 5% PBS (0.585 S/m) (B) Representative pictures depicting the parts and delivery process of fluorescein (FL, a model compound) taken after 4 minutes of applied current for 4 sutures: (i) Nylon (Ethilon, monofilament); (ii) Polyamide (Supramid, twisted and coated); (iii) Polyglactin 910 (Vycril, braided and coated); (iv) Polyglicolic acid (Surgicryl, braided and coated). Stiffness of the hydrogel was 4.3 kPa. Sample was loaded upon thread inlet segment with a 2 μL drop of a 1.0 μg/mL solution of FL. Scale bar is 2.5 mm.