Skip to main content
. 2020 Apr 30;25(4):045002. doi: 10.1117/1.JBO.25.4.045002

Table 2.

Absorption coefficient μa and reduced scattering coefficient μs of human whole blood. The blood oxygen saturation was 96%.

Wavelength (nm) μa (mm1) μs (mm1)
405 176.03 2.53
532 23.43 2.11
595 3.89 1.96
632 0.39 1.88
694 0.19 1.77
755 0.32 1.68
800 0.44 1.61
980 0.59 1.41
1064 0.30 1.34