Table 3. Influence of implant location and type of prosthesis on technical complications and CBL in NDIs and RDIs.

Variable Technical complication rate P value CBL (mm) P value
NDI 0.041a) 0.768
Anterior region 8.1 (5/61)b) 1.01±0.17 (n=61)
Posterior region 16.9 (9/53)b) 1.26±0.31 (n=53)
RDI 0.824 0.446
Anterior region 1.35 (1/74) 1.25±0.12 (n=74)
Posterior region 6.3 (3/47) 1.31±0.22 (n=47)
NDI 0.039a) 0.022a)
Single crown 6.5 (3/46) 1.03±0.14 (n=46)
Splinted crown 13.2 (9/68)b) 1.51±0.33 (n=68)
RDI 0.714 0.946
Single crown 2.5 (1/39) 1.19±0.12 (n=39)
Splinted crown 2.4 (2/82) 1.67±0.25 (n=82)

Data are shown as mean±standard deviation or number (%).

CBL: crestal bone loss, NDI: narrow-diameter implant, RDI: regular-diameter implant.

a)Statistically significant difference at P<0.05; b)Statistically significant difference in subgroups between NDIs and RDIs at P<0.05.