Skip to main content
. 2020 Apr 24;11:264. doi: 10.3389/fneur.2020.00264

Table 3.

Lesion and procedural details (mm).

No. Success Side Approach Stump 1st GW 2nd GW Balloon Stent
1 L Ante → Retro O Super-slide Synergy 8 ×40 Precise
9 ×30
2 L Ante O Super-slide Admiral 7 ×40 Precise
9 ×30
3 L Ante B Super-slide CTO ClearStream 6 ×60 Smart
8 ×60
4 L Retro / Super-slide CTO Admiral 6 ×60 Fluency
9 ×60
5 L Ante B Super-slide Admiral 7 ×40 Precise
9 ×30
6 L Ante B Super-slide CTO Admiral 6 ×40 Precise
9 ×30
7 L Ante B Super-slide CTO Bantam 6 ×60 GPS
8 ×60
8 L Ante → Retro B Super-slide CTO Sterling 6 ×30 Precise
8 ×40
9 L Ante O Super-slide Admiral 6 ×80 Everflex
8 ×60
10 L Ante → Retro O Super-slide CTO Sterling 5 ×30 Precise
8 ×40
11 L Ante O Super-slide CTO Sterling 5 ×30 BLUE 7
×18
12 R Ante → Retro O Super-slide CTO Sterling 7 ×30 Precise 9
×30
13 L Ante B Super-slide Admiral 6 ×60 GPS 8
×80
14 L Ante O Super-slide FOXPLUS 6 ×40 Express LD
8 ×17
15 L Ante O Super-slide Admiral 6 ×40 GPS
8 ×60
16 R Ante O Super-slide CTO Admiral 6 ×40 COMPLETE
8 ×60
17 L Ante B Super-slide Admiral 4 ×60 Scuba
8 ×30
18 L Ante B Super-slide Admiral 5 ×80 Dynamic
8 ×25
19 X L Ante → Retro O Super-slide CTO
20 X L Ante → Retro O Super-slide CTO
21 L Ante B Super-slide Admiral 7 ×40 Dynamic
8 ×25
22 L Ante B Super-slide Admiral 5 ×30 Precise

8 ×30
23 L Ante → Retro 0 Super-slide CTO Admiral
6 ×40
Precise
9 ×30

Stump: B for beaklike, O for obtuse.

Balloon:

Synergy (Boston Scientific), Admiral (Medtronic), ClearStream (ClearStream Technologies), Bantam (ClearStream Technologies), Sterling (Boston Scientific), FOXPLUS (Abbott).

Stent:

A. Self-expandable stent

Precise (Cordis), Smart (Cordis), GPS (EV3), Everflex (EV3), COMPLETE (Medtronic).

B. Balloon expandable stent

BLUE (Cordis), Express LD (Cordis), Scuba (INVATEC), Dynamic (Biotronik).

C. Cover stent

Fluency (BARD).