Skip to main content
. 2019 Nov 27;146(5):3800–3810. doi: 10.1121/1.5133393

TABLE IV.

Otoprotection paradigms in which mice were exposed to octave band noise.

Article ID (from Hammill, 2017) Reference Sample size Level (dB SPL) Duration (hr:min) Strain Age Weight range (grams) Notes
83 Peppi et al. (2011) 4–7 100 02:00 C57/BL/6J (B6) 6 weeks 18–25 SD/SEM not specified
163 Brown et al. (2014) Not reported 90 02:00 C57BL/6 8–10 weeks NR SD
78 Rewerska et al. (2013) 80 110 08:00 C57BL/6 6 weeks NR SD
77 Samson et al. (2008) Not reported 110 04:00 C57BL/6 12 weeks NR SEM
83 Peppi et al. (2011) Not reported 102 02:00 CBA/CaJ (CB) 10–12 weeks NR SEM
38 Le Prell et al. (2011) 16 113–116 02:00 CBA/J 5–6 weeks 25–35 SEM
45 Honkura et al. (2016) 7–8 96 02:00 Nrf2 knockout (Nrf2-/-) (C57BL/6) 6–7 weeks 17–20 SEM
95 Nagashima et al. (2010) 4 90 01:00 Std-ddY adult 26–28 SD/SEM not specified
95 Nagashima et al. (2010) 4 100 01:00 Std-ddY adult 26–28 SD/SEM not specified
95 Nagashima et al. (2010) 4 110 01:00 Std-ddY adult 26–28 SD/SEM not specified
214 Yamaguchi et al. (2014) Not reported 110 01:00 Std-ddY adult 26–28 SEM
95 Nagashima et al. (2010) 4 120 01:00 Std-ddY adult 26–28 SD/SEM not specified
45 Honkura et al. (2016) 7–8 96 02:00 Wild 6–7 weeks 17–20 SEM
163 Brown et al. (2014) Not reported 90 02:00 Wild type 8–10 weeks NR SD