Skip to main content
. 2020 Apr 23;2020:1087024. doi: 10.1155/2020/1087024

Table 2.

Impact property at room temperature of EK61 superalloy after long-term aging.

Aging time (h) Aged at 700°C Aged at 750°C
Akv (J) Error Akv (J) Error
30 49.0 ±7.08 47.0 ±7.37
100 37.0 ±3.06 37.5 ±9.09
200 38.5 ±2.75 32.0 ±10.04
500 27.5 ±1.89 30.0 ±8.01
1000 16.5 ±3.21 26.0 ±2.25