TABLE II. Numbers of Particles in Different Initial Diameter Ranges Emitted in One Cough and One Sneeze According to Duguid.

Diameter Range (μm) Number of Particles in a Cough Number of Particles in a Sneeze
1–2 50 26,000
2–4 290 160,000
4–8 970 350,000
8–16 1600 280,000
16–24 870 97,000
24–32 420 37,000
32–40 240 17,000
40–50 110 9000
50–75 140 10,000
75–100 85 4500
100–125 48 2500
125–150 38 1800
150–200 35 2000
200–250 29 1400
250–500 34 2100
500–1000 12 1000
1000–2000 2  

Source: Data from Duguid, “The Size and Duration of Air-Carriage of Respiratory Droplets and Droplet-Nuclei.” Journal of Hygiene 4:471–480, Table 3 (1946).