Published in final edited form as: J Magn Reson Imaging. 2019 May 2;51(1):175–182. doi: 10.1002/jmri.26766

TABLE 3.

Summary of Detection and Segmentation Metrics (Mean Value ± Standard Deviation)

A: Voxel-by-voxel detection accuracy using ROC statistics*
# of metastases AUC Sensitivity Specificity
  1 to 3 0.99 ± 0.01 98 ± 3% 98 ± 2%
  4 to 10 0.97 ± 0.05 92 ± 10% 97 ± 3%
  >10 0.97 ± 0.03 92 ± 7% 95 ± 3%
  All cases 0.98 ± 0.04 94 ± 8% 97 ± 3%
B: Detection and segmentation accuracy at an optimal probability threshold**
# of metastases Dice Recall Precision
  1 to 3 0.76 ± 0.20 0.54 ± .026 0.79 ± 0.27
  4 to 10 0.83 ± 0.04 0.59 ± 0.21 0.76 ± 0.22
  >10 0.78 ± 0.05 0.44 ± 0.18 0.81 ± 0.11
  All cases 0.79 ± 0.12 0.53 ± 0.22 0.79 ± 0.20
C: Lesion-by-lesion detection accuracy at an optimal probability threshold**
# of metastases Sensitivity FP (no size limit) FP (10 mm3 size limit)
  1 to 3 92 ± 25% 3.2 ± 4.0 1.7 ± 2.0
  4 to 10 81 ± 19% 8.5 ± 9.8 4.4 ± 6.0
  >10 76 ± 20% 13.1 ± 18.9 4.1 ± 10.3
  All cases 83 ± 22% 8.3 ± 12.9 3.4 ± 7.0

AUC = area under the receiver operating characteristic (ROC) curve; FP = false positive.

*

Sensitivity and specificity were determined by using the maximum value of Youden’s index.

**

The metrics were estimated using an optimal probability threshold of 0.93, as determined from the development set.