Table 2. Predictors of filter failure in CVVH patients with liver failure and increased bleeding risk.
Univariate Cox regression | Multivariate Cox regression | Multivariate Cox regression adjusted the important clinical parameters | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
HR | 95%CI | P value | HR | 95%CI | P value | HR | 95%CI | P value | ||
Anticoagulation strategy (RAC/no-anticoagulation) | 0.48 | 0.295–0.779 | 0.003 | 0.392 | 0.222–0.695 | 0.001 | 0.459 | 0.259–0.815 | 0.008 | |
Filter Type (M100 / AV600) | 0.578 | 0.180–1.856 | 0.357 | - | - | - | 109626.395 | 0.000 | 0.974 | |
Vascular access | 0.325 | 0.079–1.337 | 0.119 | - | - | - | 0.384 | 0.092–1.604 | 0.19 | |
PLT | 0.994 | 0.990–0.999 | 0.008 | 0.997 | 0.993–1.001 | 0.182 | 0.996 | 0.992–1.001 | 0.99 | |
APTT | 1.005 | 1.000–1.010 | 0.045 | 1.007 | 1.002–1.012 | 0.004 | 1.008 | 1.001–1.015 | 0.018 | |
INR | 1.001 | 0.999–1.003 | 0.284 | - | - | - | 1.010 | 0.822–1.242 | 0.922 | |
HBG | 1.003 | 0.996–1.010 | 0.34 | - | - | - | 1.009 | 1.001–1.018 | 0.036 |
RCA, Regional citrate anticoagulation; CVVH, continuous venovenous hemofiltration; PLT, platelet; APTT, activated partial thromboplastin time; INR, international normalized ratio; HBG, hemoglobin.