TABLE III.
Deformability studies of breast cancer cells.
| MCF-7 cell stiffness | MDA-MB-231 cell stiffness | Measurement technique | Study |
|---|---|---|---|
| … | 182 ± 34.74 Pa | Constricted microchannel | 17 |
| 3–4.5 kPa | 4–6 kPa | Atomic force microscopy | 18 |
| 36 ± 8 Pa | 18 ± 10 Pa | Optical tweezers | 19 |
| 87.3 ± 47.8 kPa | 55.6 ± 20.1 kPa | Atomic force microscopy | 16 |
| 30.2 ± 15.0 Pa | 12.6 ± 6.1 Pa | Optical tweezers | 16 |
| 285.1 ± 127 kPa | 277.3 ± 63.1 kPa | Atomic force microscopy | 87 |
| 275.2 ± 157.4 kPa | 257.5 ± 98.4 kPa | MEMS resonant sensor | 87 |
| 1.04 ± 0.27 kPa | … | Atomic force microscopy | 88 |
| 800 ± 20 Pa | 500 ± 25 Pa | Atomic force microscopy | 89 |
| … | 0.40 ± 0.22 kPa | Atomic force microscopy | 90 |
| 300–450 Pa | … | Atomic force microscopy | 91 |