Skip to main content
. 2019 Oct 7;62(10):3763–3770. doi: 10.1044/2019_JSLHR-S-19-0127

Table 3.

Acoustic contrasts produced by speech sound disorder–collapse speakers.

Speaker Acoustic measure M (SD)
t p Effect size (Cohen's d)
s sh
A Kurtosis 2.0 (2.5) 5.3 (4.2) −2.507 .020 0.95
B Center of gravity
Skewness
11047 (1797)
−0.095 (.69)
9701 (1652)
0.44 (.48)
2.064
−2.396
.049
.024
0.78
0.90
C Center of gravity 9810 (1348) 8736 (637) 2.697 .012 1.02
D Duration 211.4 (24.0) 236.3 (34.3) −2.249 .033 0.84
E Center of gravity 8058 (946) 6851 (1850) 2.325 .027 0.82