Skip to main content
. 2020 Apr 21;2020:7204315. doi: 10.1155/2020/7204315

Table 1.

Linear equations, correlation coefficients, lower limit of quantification, and detection limit of hirsutine and hirsuteine in mouse tissue.

Compound Name Linear equations Concentration range (ng/mL) Correlation coefficient Lloq Lod
Hirsutine Kidney y = 0.0008x + 0.0006 2–5000 0.9983 2 0.05
Liver y = 0.0007x + 0.0003 2–5000 0.9982 2 0.05
Heart y = 0.0009x + 0.0002 2–5000 0.9967 2 0.05
Spleen y = 0.0008x + 0.0005 2–5000 0.9981 2 0.05
Brain y = 0.0005x + 0.0004 2–5000 0.9952 2 0.05
Lung y = 0.0004x + 0.0002 2–5000 0.9971 2 0.05

Hirsuteine Kidney y = 0.0008x + 0.0007 2–5000 0.9977 2 0.05
Liver y = 0.0006x + 0.0004 2–5000 0.9984 2 0.05
Heart y = 0.0007x + 0.0004 2–5000 0.9973 2 0.05
Spleen y = 0.0009x - 0.0001 2–5000 0.9991 2 0.05
Brain y = 0.0006x - 0.0002 2–5000 0.9975 2 0.05
Lung y = 0.0004x + 0.0002 2–5000 0.9969 2 0.05