Table 3.

Performance Results of the Selected Alternative Models Developed with Chiang et al. Dataset

Fault Optimal feature subset size AUC Accuracy Detection rate False negative rate False alarm rate Latency (min)
8* 4 99.2 95.9 95.8 4.2 3.1 63
17* 27 99.1 93.4 92.1 7.9 0.0 75
*

Imply that the end-model is selected for online implementation.