Skip to main content
. Author manuscript; available in PMC: 2020 May 6.
Published in final edited form as: AIChE J. 2018 Dec 18;65(3):992–1005. doi: 10.1002/aic.16497

Table 6.

Comparison of Fault Detection Rate between the Fault-Specific Models Producing Highest Fault Detection Rate of this Study and the Models Reported in the Literature.14,25,52 Best results of Xiao et al. are adopted. (Highest fault detection rates are bolded.)

Ref. Mahadevan and Shah25 Xiao et al.52 Yin et al.26 This study
Faults PCA-T2 PCA-Q DPCA-T2 DPCA-Q One-class SVM Two-class SVM Two-class SVM Two-class SVM
1 99.2 99.8 99.4 99.5 99.8 99.5 99.5 99.9
2 98.0 98.6 98.1 98.5 98.6 98.3 98.1 99.1
4 4.4 96.2 6.1 100.0 99.6 47.4 99.9 100.0
5 22.5 25.4 24.2 25.2 100.0 45.2 90.8 100.0
6 98.9 100.0 98.7 100.0 100.0 99.2 60.1 100.0
7 91.5 100.0 84.1 100.0 100.0 70.1 98.9 100.0
8 96.6 97.6 97.2 97.5 97.9 97.4 96.0 100.0
10 33.4 34.1 42.0 33.5 87.6 68.0 81.0 99.4
11 20.6 64.4 19.9 80.7 69.8 65.8 80.2 100.0
12 97.1 97.5 99.0 97.6 99.9 98.8 97.8 100.0
13 94.0 95.5 95.1 95.1 95.5 95.0 92.5 100.0
14 84.2 100.0 93.9 100.0 100.0 93.9 91.0 100.0
16 16.6 24.5 21.7 29.2 89.8 73.1 89.4 100.0
17 74.1 89.2 76.0 94.7 95.3 75.2 81.6 98.2
18 88.7 89.9 88.9 90.0 90.0 89.3 89.5 95.3
19 0.4 12.7 0.7 24.7 83.9 43.6 85.9 100.0
20 29.9 45.0 35.6 51.0 90.0 69.0 80.5 100.0
21 26.4 43.0 35.6 44.2 52.8 59.4 - 100.0