Table 12.
Exergo-environmental calculations for standalone geothermal cycle.
| Component | (pts/s) | (pts/kJ) | (pts/kJ) | (pts/s) | (pts/s) | (pts/s) | (%) | |
|---|---|---|---|---|---|---|---|---|
| ORC Condenser | 6.25E-08 | - | - | - | - | - | - | - |
| ORC Evaporator | 4.77E-06 | 0 | 6.40E-10 | 0 | 4.77E-06 | 0 | Inf | 100 |
| ORC Pump | 2.61E-08 | 3.68E-09 | 4.96E-09 | 3.06E-06 | 3.09E-06 | 3.68E-07 | 0.3462 | 3.29 |
| ORC Recuperator | 1.75E-07 | 1.20E-09 | 2.41E-09 | 5.21E-07 | 6.96E-07 | 1.75E-07 | 1.0095 | 5.00E+01 |
| ORC Turbine | 1.29E-05 | 1.20E-09 | 3.68E-09 | 8.10E-06 | 2.10E-05 | 1.26E-06 | 2.0698 | 91.1 |