Skip to main content
. 2020 Apr 10;6(4):e03758. doi: 10.1016/j.heliyon.2020.e03758

Table 12.

Exergo-environmental calculations for standalone geothermal cycle.

Component Y˙(pts/s) bF(pts/kJ) bP(pts/kJ) BF(pts/s) BP(pts/s) BD(pts/s) rb fb(%)
ORC Condenser 6.25E-08 - - - - - - -
ORC Evaporator 4.77E-06 0 6.40E-10 0 4.77E-06 0 Inf 100
ORC Pump 2.61E-08 3.68E-09 4.96E-09 3.06E-06 3.09E-06 3.68E-07 0.3462 3.29
ORC Recuperator 1.75E-07 1.20E-09 2.41E-09 5.21E-07 6.96E-07 1.75E-07 1.0095 5.00E+01
ORC Turbine 1.29E-05 1.20E-09 3.68E-09 8.10E-06 2.10E-05 1.26E-06 2.0698 91.1