Skip to main content
. 2020 Apr 10;6(4):e03758. doi: 10.1016/j.heliyon.2020.e03758

Table 14.

Emergo economic analysis results of the standalone geothermal cycle (first mode).

component U˙(sej/s) Mf(sej/kJ) Mp(sej/kJ) M˙F(sej/s) M˙P(sej/s) M˙D(sej/s) rm fm(%)
ORC Condenser 8.0563E+08 - - - - - - -
ORC Evaporator 3.1072E+08 1.7485E+06 1.9491E+06 1.4216E+10 1.4526E+10 1.1845E+08 0.1147 20.78
ORC Pump 1.2555E+09 4.6850E+06 8.2696E+06 3.8944E+09 5.1499E+10 9.7683E+08 0.7651 56.24
ORC Recuperator 2.7547E+07 3.0382E+06 4.6676E+06 1.3205E+09 1.3480E+09 4.4302E+08 0.5363 5.85
ORC Turbine 6.1952E+09 3.0382E+06 4.6850E+06 2.0509E+10 2.6705E+10 3.1915E+09 0.5420 66.00