Skip to main content
. 2020 Apr 10;6(4):e03758. doi: 10.1016/j.heliyon.2020.e03758

Table 16.

Emergo environmental calculations for standalone geothermal cycle (first mode).

Component V˙(sej/s) Nf(sej/kJ) Np(sej/kJ) N˙F(sej/s) N˙P(sej/s) N˙D(sej/s) rn fn(%)
ORC Condenser 8.4844E+06 - - - - - - -
ORC Evaporator 6.4780E+08 6.86E+09 7.5705E+06 5.5774E+10 5.6422E+10 4.6474E+08 0.1036 12.23
ORC Pump 5.7135E+05 1.1088E+07 1.4801E+07 9.2168E+09 9.2174E+09 2.3118E+09 0.3349 0.0247
ORC Recuperator 2.3728E+07 9.2533E+06 1.4007E+07 4.0217E+09 4.0454E+09 1.3493E+09 0.5138 1.73
ORC Turbine 7.3731E+08 9.2533E+06 1.1088E+07 6.2464E+10 6.3201E+10 9.7201E+09 0.1983 7.05