Skip to main content
. 2020 Apr 10;6(4):e03758. doi: 10.1016/j.heliyon.2020.e03758

Table 7.

Validation of the first and second mode of simulation and Computer code results.

Main parameters first mode results
second mode results
Computer code Simulation Error (%) Computer code Simulation Error (%)
Flow rate of cooling water (kg/s) 660.98 662 0.15 664.59 676.2 1.72
Flow rate of organic Rankine cycle (kg/s) 151.58 151.2 0.25 153.90 154.5 0.39
Geothermal inlet heat (kW) 32734 32730 0.01 33027 33600 1.71
Net power output of organic Rankine cycle (kW) 4728 4651 1.66
Net power output of topping cycle (kW) 1194.8 1155.2 3.43
Net power output (kW) 4592.2 4412 4.08 5922.7 5734.9 3.27
Energy efficiency (%) 14.03 13.48 4.08
Energy efficiency of organic Rankine cycle (%) 14.32 13.84 3.45
Energy efficiency of topping cycle (%) 15.53 15.01 3.46
Steam cycle flowrate (kg/s) 3.171 3.145 0.83
Heat transfer fluid flowrate (kg/s) 23.481 23.5 0.08