Skip to main content
. 2019 Dec 4;19(3):1015–1034. doi: 10.1007/s10237-019-01268-5

Table 2.

Summary LA volume changes during simulated atrial contraction

i V0 (ml) Vinfl (ml) Vcont (ml) IF (%) EF (%)
1 101.03 156.47 98.81 154.9 36.9
2 61.04 99.31 67.57 162.2 32.0
3 51.11 83.36 62.32 163.1 25.2

i Case index; V0 reference volume; Vinfl volume after inflation, prior to atrial contraction; Vcont minimum atrial volume at contracted state; inflation fraction (IF) is Vinfl/V0; and ejection fraction (EF) is (Vinfl-Vcont)/Vinfl