Skip to main content
. 2020 Jan 29;2020:7194780. doi: 10.1155/2020/7194780

Table 2.

Chlorine residual, electrical conductivity, and nitrate measurements.

Chlorine residual (mg/liter) Electrical conductivity (μS/cm) Nitrate NO3− (mg/L)
Local standard PWA 0.2–1 PWA 250 PWA 70

International standard WHO 0.2–1 WHO 250 WHO 50

DWSS Mean ± SD Min Max Samples met the standard (%) Mean ± SD Min Max Samples met the standard (%) Mean ± SD Min Max Samples met the standard (%)

Catchment (n = 109) 0.19 ± 0.3 0 0.9 31.2 2165.1 ± 969.8 750 5000 0 180.4 ± 108.9 35 445 12.8

Treatment plant (n = 109) 0.09 ± 0.2 0 0.9 18.3 223.1 ± 162.6 60 1010 71.5 18.8 ± 12.9 1.32 60 100

Tanker truck (n = 197) 0.03 ± 0.1 0 0.9 14.7 226.4 ± 187.6 50 1200 70.7 19.9 ± 12.9 1.32 64 100

Desalinated water at household (n = 384) 0.01 ± 0.06 0 0.3 4.3 235.4 ± 186.4 50 1300 41.9 21.9 ± 13.3 4.91 68 100

Municipal water at household (n = 384) 0.19 ± 0.3 0 0.9 30.2 2000.3 ± 908.5 750 5000 0 202.6 ± 11.02 43 456 8.8