Skip to main content
. 2020 Apr 17;12085:688–700. doi: 10.1007/978-3-030-47436-2_52

Table 4.

Anomaly Detection Performance on KDD99 with different ratios of anomalies during training.

Radio CADGMM DAGMM OC-SVM
Precision Recall F1 Precision Recall F1 Precision Recall F1
1% 95.53 97.04 96.28 92.01 93.37 92.68 71.29 67.85 69.53
2% 95.32 96.82 96.06 91.86 93.40 92.62 66.68 52.07 58.47
3% 94.83 96.33 95.58 91.32 92.72 92.01 63.93 44.70 52.61
4% 94.62 96.12 95.36 88.37 89.89 89.12 59.91 37.19 45.89
5% 94.35 96.04 95.3 85.04 86.43 85.73 11.55 33.69 17.20