Skip to main content
. 2020 May 8;129:104427. doi: 10.1016/j.jcv.2020.104427

Table 2.

Comparison of the Stanford Health Care Assay with other Nucleic Acid Amplification Tests for detection of SARS-CoV-2 RNA in clinical samples.

Atila iAmp N/ORF1ab
Detected Not Detected Total
SHC EUA Detected 24 5 29
Not Detected 0 50 50
Total 24 55 79
Altona E gene
Detected Not Detected Total
SHC EUA Detected 26 4 30
Not Detected 0 50 50
Total 26 54 80
Altona S gene
Detected Not Detected Total
SHC EUA Detected 26 4 30
Not Detected 0 50 50
Total 26 54 80
CDC N1
Detected Not Detected Total
SHC EUA Detected 26 4 30
Not Detected 0 50 50
Total 26 54 80
CDC N2
Detected Not Detected Total
SHC EUA Detected 27 3 30
Not Detected 0 50 50
Total 27 53 80