. 2020 May 8;10:7780. doi: 10.1038/s41598-020-64622-z

Figure 3.

Figure 3

Interval changes in the middle molecules levels. (a) β2-microglobulin. (b) Kappa free light chain. (c) Lambda free light chain. The error bars indicate the standard error. The specification of the MCO and high-flux dialyzers are as follows (dialyzer [type of dialyzer, membrane polymer, inner diameter, wall thickness, effective surface area]): Theranova 400 (medium cut-off, polyarylethersulfone-PVP, 180 μm, 35 μm, 1.7 m2); FX CorDiax 80 (high-flux, polysulfone-PVP, 185 μm, 35 μm, 1.8 m2); FX CorDiax 60 (high-flux, polysulfone-PVP, 185 μm, 35 μm, 1.4 m2), respectively. Abbreviations: MCO, medium cut-off; FX80, FX CorDiax 80; FX60, FX CorDiax 60; κFLC, kappa free light chain; λFLC, lambda free light chain; PVP, polyvinylpyrrolidone.