Table 3:

Leave-one-out analysis of nine subsets of LCL specimens using regression fits from all MCL and LCL specimens (total dataset), fits specific to ligament type, and specimen-specific regression fits. Shown are the mean (b, bias), standard deviation (p, precision), and root-mean-square error (RMSE).

Predicted Specimen Stress Error Metric [MPa]
Total Dataset Ligament Type Specimen Specific
b p RMSE b p RMSE b p RMSE
LCL 1 0.36 0.26 0.45 0.51 0.40 0.65 0.32 0.22 0.39
LCL 2 0.69 0.46 0.83 0.20 0.13 0.24 0.13 0.10 0.16
LCL 3 0.92 0.47 1.03 0.54 0.27 0.60 0.13 0.09 0.16
LCL 4 0.40 0.33 0.52 0.59 0.40 0.71 0.34 0.28 0.44
LCL 5 0.42 0.34 0.54 0.33 0.30 0.44 0.23 0.27 0.36
LCL 6 0.86 0.60 1.04 0.40 0.25 0.47 0.32 0.18 0.36
LCL 7 0.91 0.70 1.15 1.32 1.01 1.66 0.38 0.34 0.51
LCL 8 2.73 1.98 3.37 2.08 1.57 2.61 0.35 0.34 0.49
LCL 9 1.86 1.16 2.19 1.24 0.80 1.47 0.63 0.63 0.89
Average 1.02 1.14 1.53 0.80 0.92 1.22 0.32 0.35 0.47