Table 2.

Optical coherence tomography findings

M1 after HTx M12 after HTx Change (M12 - M1) P-value (after Bonferroni correction)
Mean luminal area (mm2) 9.0±2.5 8.0±2.4 −1.0±1.5 <0.001
Mean intimal thickness (μm) 106.5±40.4 130.1±53.0 23.6± 30.3 <0001
Maximal intimal thickness (μm) 174.5±92.3 223.3±106.9 79.1±71.3 <0.001
Mean medial thickness (μm) 82.2±22.0 83.7±21.2 1.5±11.7 1
Mean intimal+medial thickness (μm) 188.7±58.6 213.8±70.2 25.1±37.7 <0.001
Max intimal+medial thickness (μm) 274.3±107.7 324.5±122.0 87.0±79.3 <0.001
Mean intimal/medial ratio 1.4±0.3 1.6±0.4 0.3±0.3 <0.001

HTx – heart transplant; M – month; mm – millimetres; μm – micrometres