Photostimulated luminescence (PSL) counts and PSL ratios of E-beam irradiated medicinal herbs (Unit: photon counts/60 s)

Sample Irradiation dose (kGy) PSL1 PSL2 PSL ratio (PSL2/PSL1)a
Cnidii Rhizoma 0 658 ± 36b (−)c 850,067 ± 162,167 (+) 1294.20 ± 259 (N)
1 822,687 ± 16,683 (+) 1157,451 ± 21,819 (+) 1.41 ± 0.04 (I)
5 1074,822 ± 31,775 (+) 1265,096 ± 36,183 (+) 1.18 ± 0.05 (I)
10 3227,228 ± 87,806 (+) 5478,056 ± 58,133 (+) 1.70 ± 0.05 (I)
Alismatis Rhizoma 0 339 ± 30 (−) 320,250 ± 5012 (+) 950.74 ± 86 (N)
1 56,840 ± 1829 (+) 279,049 ± 15,476 (+) 4.91 ± 0.26 (I)
5 74,199 ± 7293 (+) 327,863 ± 17,088 (+) 4.45 ± 0.47 (I)
10 209,663 ± 19,835 (+) 659,032 ± 19,044 (+) 3.17 ± 0.34 (I)

aPSL Ratio ≤ 10: irradiated (I), ratio > 10: non-irradiated (N)

bThe values are expressed as mean ± standard deviation (n = 5)

cThreshold value: T1 = 700, T2 = 5000, (−) < T1, T1 < (M) < T2, (+) > T2